MOTOROLA MVME147-012 Counter module
General I/O Port The general I/O port includes:
• 16 24 VDC inputs Sink or source in groups of eight Inputs 1 and 9 can trigger an interrupt on the rising or falling edge
• +24 VDC and 24 V Common
• 16 24 VDC outputs Source only 250 mA output capacity short circuit protected
There are 16 DC outputs on the general connector. These outputs get their power internally from the MMC.
General Outputs Connected to Loads
There are 16 general inputs on the general connector. The inputs are configured as two groups of eight. Each group can be configured as sourcing or sinking. Connect the DCSS pin to +24 V for a sourcing configuration. Connect the DCSS pin to COM for a sinking configuration. You can use the internal +24 V supply. See Figure 10 below
We have a large amount of inventory and high quality, out of production control system components, DCS system accessories, robot system accessories, large servo system spare parts. PLC module, DCS module, CPU module, IO module, DO module, AI module, DI module, network communication module, Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output module, redundancy module, power module, relay output module, relay input module, processor module and other major brands.