ALSTOM MVAJ27L1FB0784D Pulse input module
Program the supply to full-scale voltage. When the output voltage is at full-scale ± 0.1 %, send the command : "TRVG". This will store the voltage read gain value in the EEPROM for later use in readback calculations. Send command "MV" to initiate a read of the voltage channel. Check to make sure the reading is now correct (voltage should equal full scale). Program and measure the voltage for several points throughout the supply's range. The programming and readback should track closely.
CURRENT CHANNEL CALIBRATION:
Turn circuit breaker to OFF position. Either connect the load to the power supply and adjust it such that the supply will be able to put out its full current or connect the shorting strap to the power supply. If using an external shunt connect the shunt in series with the load or shorting strap. Turn circuit breaker to ON position. Send command "SR".
We have a large amount of inventory and high quality, out of production control system components, DCS system accessories, robot system accessories, large servo system spare parts. PLC module, DCS module, CPU module, IO module, DO module, AI module, DI module, network communication module, Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output module, redundancy module, power module, relay output module, relay input module, processor module and other major brands.