Home > Product > PLC programmable module > 140DDO84300 Digital module

  • 140DDO84300 Digital module
  • 140DDO84300 Digital module
  • 140DDO84300 Digital module
140DDO84300 Digital module 140DDO84300 Digital module 140DDO84300 Digital module

140DDO84300 Digital module

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

140DDO84300 Digital module

• Chips can be prepared and left idle on the instrument for up to 8 hours. This workflow allows analysis of samples as needed throughout the day without having to re-prep the chip as long as the maximum number of samples per chip prep is not exceeded. • PerkinElmer recommends the chip be re-prepared after it has been idle for 8 hours. Samples • Prepared sample plates should be free of gas bubbles and particulate debris, both of which may inhibit sipper flow. • Sample plates containing gas bubbles and/or particulate debris should be spun down at 3000 rpm (1250 rcf) prior to analysis. • Up to 96 samples in a 96-well or 384-well plate can be run with a single chip preparation.

Aspirating with a pipette can leave used reagents in the chip wells. For this reason, PerkinElmer recommends vacuuming the wells instead. This can be accomplished by attaching a permanent pipette tip to a house vacuum line with trap (Figure 20). To avoid contamination, use a new disposable pipette tip over the permanent tip for each chip aspirated (Figure 21).

Other Considerations

 • Chips should be stored at 2 - 8°C prior to first use. • Cover the wells with Parafilm® to prevent evaporation and store at 2 - 8°C until next use. If using the chip again within 24 hours it may be left at room temperature. Allowing the chip wells to dry may lead to changes in chip performance. • Do not allow the liquid in the chip container to freeze, as this may lead to poor chip performance. Do not submerge the chip in any solution. • The entire chip surface must be thoroughly dry before use. • The sipper must be kept immersed in fluid at all times and should not be exposed to an open environment for long periods of time. • Use care in chip handling to prevent sipper damage. Damage to the sipper can result in inconsistent sampling. • Avoid exposing the chips to dust by keeping them in a closed environment such as in the chip container or in the instrument before and after chip preparation.

Label Licenses

 This product is provided under an intellectual property license from Life Technologies Corporation. The purchase of this product conveys to the buyer the non-transferable right to use the data for internal research and training purposes solely in combination with PerkinElmer, Inc. instrumentation, and not to generate revenue, which may include, but is not limited to use of the product: (1) in manufacturing or in quality assurance or quality control of a commercial product; (2) to provide a service, information, or data for a fee or other consideration; (3) for therapeutic or prophylactic purposes; (4) for diagnostic use; and (5) for resale, whether or not such items are resold for use in research. For information on purchasing a license to this product for any other purposes, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@lifetech.com. Rights of Use The chip and reagents supplied with this kit are sold with limited rights of use. The chip may only be used with the specific quantity of reagents supplied with this kit. The purchaser has no right or license to refurbish, reuse, remanufacture, or otherwise use the chip with any other reagents than those specifically supplied in this kit. For more information on the terms and conditions of use of these chips and reagents, please read your LabChip GX Touch User Guide and refer to the applicable label license. The reagent kit contains materials that are provided under a license from Life Technologies Corporation, for research use only. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks and registered trademarks are the property of their respective holders.

Obtain the latest price of 140DDO84300 Digital module