Home > Product > PLC programmable module > RELIANCE 0-51845 Voltage monitoring module

  • RELIANCE 0-51845 Voltage monitoring module
RELIANCE 0-51845 Voltage monitoring module

RELIANCE 0-51845 Voltage monitoring module

RELIANCE 0-51845 Voltage monitoring module

Generated heat of the converter unit/drive unit Table 4.1 indicates the generated loss and power supply capacity under rated load per combination of the converter unit and drive unit. When the servo motors are run at less than the rated speed, the power supply equipment capacity is lower than the value in the table but the heat generated does not change. 

Since the servo motor requires 2 

times to 2.5 times greater instantaneous power for acceleration, use the power supply which ensures that the voltage lies within the permissible voltage fluctuation at the main circuit power supply terminals (L1, L2, and L3) of the converter unit. The power supply equipment capacity changes with the power supply impedance. The actually generated heat falls within the ranges at rated output and at servo-off according to the frequencies of use during operation. When designing an enclosed cabinet, use the values in the table, considering the worst operating conditions. The generated heat in table 4.1 does not include heat produced during regeneration.

                                  

Professional seller

Professional sales of major electrical brand products in the world

Overseas direct purchase of products, authentic inventory, price concessions

After sales warranty, complete models, same products, different prices and services


This article from the temporal Ming sheng automation equipment co., LTD., reproduced please attach this link: http://www.stockdcs.com/

Obtain the latest price of RELIANCE 0-51845 Voltage monitoring module