Home > Product > Servo control system > WOODWARD 8701-758 5601-1126 Servo speed governor

  • WOODWARD 8701-758 5601-1126 Servo speed governor
  • WOODWARD 8701-758 5601-1126 Servo speed governor
  • WOODWARD 8701-758 5601-1126 Servo speed governor
WOODWARD 8701-758 5601-1126 Servo speed governor WOODWARD 8701-758 5601-1126 Servo speed governor WOODWARD 8701-758 5601-1126 Servo speed governor

WOODWARD 8701-758 5601-1126 Servo speed governor

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

WOODWARD 8701-758 5601-1126 Servo speed governor

Operating modes of the serial interface COM1 The operating mode of the interface has to be set according to the application in each case: – Programming and test or – Man–machine–communication MMC Active mode: The active mode is used for programming and testing the central unit, i.e. it gives the user access to all the programming and test functions of the central unit.

assive mode: The passive mode is used to perform a communication configured with the DRUCK and EMAS blocks between the user program and a device connected to the serial interface

Temporary interruption of the passive mode While a communication between the DRUCK or EMAS blocks and a device connected to COM1 is being executed, it may be come necessary to modify the program, for example. For this purpose, you must switch over COM1 from the passive mode into the active mode.

Operating modes of the COM2 interface

 The serial interface COM2 is fixedly set to the passive mode (MMC interface). The passive mode is used to perform a communication configured with the aid of the DRUCK and EMAS blocks between the user program and a device connected to the serial interface. The application-specific initialization of COM2 can be performed using the SINIT function block.For the passive mode of COM1, the interface parameters can be changed using the SINIT function block. If the changed values are not plausible, the COM1 interface uses the default values. The interface is newly initialized each time the operating mode is switched over. The active-mode parameters are set in the active mode, whereas in the passive mode the parameters established by the SINIT block or the default values are set.

Networking interface 

The 07 KT 92 central unit is equipped with a special parallel interface. It is thus possible to network it with another bus system using an additional communication processor module. The additional communication processor has its own housing. Both housings (of the 07 KT 92 and of the communication processor) are assembled by means of a snap-on connection. 

The default End-of-text character for the sending direction (CR) is not sent. Nevertheless, this default End-of-text character (CR) must not appear in the message text of the assigned DRUCK block. 2) For the direction of reception, an End-of-text character is always necessary. This default End-of-text character (CR) must not appear neither in the message text nor in the user data of the assigned EMAS block. For the passive mode of COM2, the interface parameters can be changed using the SINIT function block. If the changed values are not plausible, the COM2 interface uses the default values. In the passive mode the parameters established by the SINIT block or the default values are set

Obtain the latest price of WOODWARD 8701-758 5601-1126 Servo speed governor