Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.
Analog I/O Module The Mark* VIeS Functional Safety Analog Input /Output (I/O) module provides an interface between the process analog sensors / actuators (10 analog inputs and two analog outputs) and the Mark VIeS Safety control logic. The Analog I/O module consists of two orderable parts: the Analog I/Opack and the Analog I/Oterminal board. All safety Analog I/O modules use the same Analog I/Opack, IS420YAICS1B. There are two DIN-rail mounted Analog I/Oterminal boards available to provide the necessary redundancy and terminal block styles. Users can select the configuration that best addresses their needs for availability and SIL level. The Analog I/O module is available in both Simplex and Triple Modular Redundant(TMR) configurations. This document discusses the Simplex Analog I/O(IS410STAIS2A) terminal board and the TMR Analog I/O(IS410TBAIS1C) terminal board. In a TMR configuration, the controller selects the median analog input values returned by the TMR I/O pack(s) (thus rejecting a high or low out of range value) and the I/Opack electronics combine the analog outputs with a patented circuit design that rejects a bad performing I/Opack. Simplex Analog I/O(STAI) Terminal Board The STAI terminal board is a compact analog input terminal board that accepts 10 analog inputs and two analog outputs, and connects to the YAIC I/Opack. The 10 analog inputs accommodate two-wire, three-wire, four-wire, or externally powered transmitters. The analog outputs are configured for 0 to 20 mA. An on-board ID chip identifies the board to the I/Opack for system diagnostic purposes.
The TBAI terminal board is an analog input terminal board used in TMR and Simplex configurations that supports 10 analog inputs and two outputs, and connects to the YAIC I/Opack. The 10 analog inputs accommodate two-wire, three-wire, four-wire, or externally powered transmitters. The analog outputs can be configured for 0 to 20 mA. Inputs and outputs have noise suppression circuitry to protect against surge and high frequency noise. The TBAI has three DC-37 pin connectors for three TMR I/Opacks or one Simplex I/Opack. The Analog I/OTerminal Board with YAIC I/OPack Specifications table provides the specifications for the Analog I/Oterminal boards available for use in the Mark VIeS Functional Safety System. For more information on the YAIC I/Opack and the STAI and TBAI terminal boards, refer to the chapter “PAIC, YAIC Analog I/O Modules” in the document Mark VIeS Functional Safety Systems for General Market Volume II: System Guide for General-purpose Applications (GEH-6855_Vol_II).
The Mark* VIe and Mark VIeS Functional Safety UCSC controller is a compact, stand-alone controller that runs application-specific control system logic. It can be used in a diverse range of applications, from small industrial controllers to large combined-cycle power plants. The UCSC controller is a base-mounted module, with no batteries, no fans, and no hardware configuration jumpers. All configuration is done through software settings that can be conveniently modified and downloaded using the Mark controls platform software configuration application, ToolboxST*, running on a Microsoft © Windows © operating system. The UCSC controller communicates with I/O modules (Mark VIe and Mark VIeS I/O packs)through on-board I/Onetwork (IONet) interfaces. The Mark VIeS Safety controller, IS420UCSCS2A, is a dual core controller that runs the Mark VIeS Safety control applications used for functional safety loops to achieve SIL 2 and SIL 3 capabilities. The Mark VIeS Safety product is used by operators that are knowledgeable in safety-instrumented system (SIS) applications to reduce risk in safety functions. The UCSCS2A controller can be configured for Simplex, Dual, and TMR redundancy. The non-safety Mark VIe controller, IS420UCSCH1B, can be interfaced with the Safety control system (through EGD protocol on UDH Ethernet port) as a controller for non-SIF loops or as a simple communication gateway to provide data with OPC ® UA Server or Modbus ® Master feedback signals, if needed by the application. The following table provides the specifications for the UCSC controllers. For more information on the UCSC controller, refer to “UCSC Controllers” in the document Mark VIeS Functional Safety Systems for General Market Volume II: System Guide for Generalpurpose Applications (GEH-6855_Vol_II).