DAC 41072001 Dual channel assembly module
witches. The sum of all the voltages shown by each respective switch position and the constant value as show on the relay nameplate, gives the required setting voltage. 1.2 Time multiplier setting switches The TMS setting is determined by the top three dual-in-line switches. The sum of all the settings indicated by each switch position and the constant value 0.125, again as shown on the nameplate, gives the required TMS setting
Warranty: 365 days Goods status: new/used Shipping method: Courier delivery
Company product range
----------------------Ruichang Mingsheng Automation Equipment Co., Ltd----------------------
PLC module, programmable controller, CPU module, IO module, DO module, AI module, DI module
Network communication module,
Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output
Module, redundancy module, power module, relay output module, relay input module, processor module
Precautions
Protective relays, although generally of robust construction, require careful treatment prior to installation and a wise selection of site. By observing a few simple rules the possibility of premature failure is eliminated and a high degree of performance can be expected. 3.2 Packing The relays are either despatched individually or as part of a panel/rack mounted assembly, in cartons specifically designed to protect them from damage.