The unit is a twin-channel safety switch unit that is self-monitoring at every ON-OFF cycle, for emergency stop devices as per DIN EN 60204-1, which is fitted with a positively guided relay. Basic function: After application of the power supply to the terminals A1/A2 and closed safety inputs, actuation of the reset button (manual start) causes the enable circuits to be closed. The enable circuits are opened by opening/de-excitation of the safety inputs.
Warranty: 365 days Goods status: new/used Shipping method: Courier delivery
Our products
A company specializes in the sales of module spare parts of global famous brands (DCS system) (robot system) (large servo control system). The company's products include distributed control system (DCS), programmable controller (PLC), MOTOROLA MVME industrial module, industrial control communication converter (Anybus), remote output/input module (RTU), industrial computer (IPC), industrial low screen screen (IPC) HMI SCSI (50, 68, 80Pin) AnyBus (Gateway) has become a global sales enterprise of industrial automation spare parts and components
Operating modes / system functions
Single or twin channel control with single channel control the two safety channels CH1 and CH2 are in parallel and with twin channel control they are switched separately.
Without cross short detection both safety channels are switched to plus potential (S12 and S31 to S11).
With cross short detection the safety channel CH1 is switched to plus potential (S11 to S12) and the safety channel CH2 against minus potential (S21 to S22).