TSC Carat 1008FC Sequential control module
Plugs and terminals connected to the field zone.
- Take the appropriate earthing measures when connecting the plugs and terminals to the field zone.
- An unshielded cable may be used for connecting the contact makers to the digital inputs.
- On the Carat 1008FC module side, the shielding must be connected to the cable shield rail (use SK 20 shield connection terminal block or similar).
- When using stranded wires, TSC recommends fastening ferrules to the wire ends. The terminals must be suitable for fastening the cross-sections of the cables in use.
If the supply is used, utilize the voltage output used for the assigned input, see Table 9. HIMA recommends using the supply of the module. If an external supply or measurement unit fails, the affected digital input on the module can be overloaded and damaged. If an external supply is required for the given application, check the switching threshold following a non-transient overload that exceeds the limit values of the module.
The inputs can be interconnected redundantly using the corresponding connector boards, see Chapters 3.6 and 4.4.
Product extension
SECURITY COMPANY BLL510
GE IC754VGF12CTD
ADEPT 10350-00104
BENTLY 1900/27
SEW 8141649.53
PROSOFT MVI69-PDPMV1
LKB LKB2211 SUPERRAC
ABB UFC921A101 3BHE024855R0101
Superior products
Main products include DCS control system spare parts, PLC system spare parts and robot system spare parts,Advantage brands: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, B&R, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft and other imported industrial parts
parameter
Product Net Depth / Length:95mm
Product Net Height:320mm
Product Net Weight:1.35 kg
Product Net Width:450mm
Voltage:240V
Made To Order:No
This article from the temporal Ming sheng automation equipment co., LTD., reproduced please attach this link: http://www.stockdcs.com/