Home > Product > DCS control system > TRICONEX MP3101S2 Redundant CARDS

  • TRICONEX MP3101S2 Redundant CARDS
  • TRICONEX MP3101S2 Redundant CARDS
  • TRICONEX MP3101S2 Redundant CARDS
TRICONEX MP3101S2 Redundant CARDS TRICONEX MP3101S2 Redundant CARDS TRICONEX MP3101S2 Redundant CARDS

TRICONEX MP3101S2 Redundant CARDS

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.

TRICONEX MP3101S2 Redundant CARDS

369PC software: Setup and monitoring software provided free with each relay. RRTD: Remote RTD Module. Connects to the 369 via a fibre optic or RS485 connection. Allows remote metering and programming for up to 12 RTDs. Complete with connecting fiber optic cable. F485: Converts communications between RS232 and RS485 / fibre optic. Used to interface a computer to the relay. CT: 50, 75, 100, 150, 200, 300, 350, 400, 500, 600, 750, 1000 (1A or 5A secondaries) HGF: Ground CTs (50:0.025) used for sensitive earth fault detection on high resistance grounded systems. 515: Blocking and test module. Provides effective trip blocking and relay isolation. DEMO: Metal carry case in which 369 is mounted. FPC15: Remote faceplate cable, 15'.

No special ventilation required as long as ambient temperature remains within specifications. Ventilation may be required in enclosures exposed to direct sunlight. OVERVOLTAGE CATEGORY II CLEANING May be cleaned with a damp cloth.

d082d79904e378397cc59202556710a7.jpg

RELAY LABEL DEFINITION

The 369 order code at the time of leaving the factory. 2. The serial number of the 369. 3. The firmware installed in the 369 at the factory. Note that this may no longer be the currently installed firmware as it may upgraded in the field. The current firmware revision may be checked in the Actual Values section of the 369. 4. Specifications for the output relay contacts. 5. Certifications the 369 conforms with or has been approved to. 6. Factory installed options. These are based on the order code. Note that the 369 may have had options upgraded in the field. The Actual Values section of the 369 may be checked to verify this. 7. Control power ratings for the 369 as ordered. Based on the HI/LO rating from the order code. 8. Pollution degree. 9. Overvoltage Category. 10. IP code. 11. Modification number for any factory ordered mods. Note that the 369 may have had modifications added in the field. The Actual Values section of the 369 may be checked to verify this. 12. Insulative voltage rating.

GUIDEFORM SPECIFICATIONS

Motor protection and management shall be provided by a digital relay. Protective functions shall include: • phase overload standard curves (51) • overload by custom programmable curve (51) • I2t modeling (49) • current unbalance / single phase detection (46) • starts per hour and time between starts • short circuit (50) • ground fault (50G/50N 51G/51N) • mechanical jam / stall Optional functions shall include: • under / overvoltage (27/59) • phase reversal (47) • underpower (37) • power factor (55) • stator / bearing overtemperature with twelve (12) independent RTD inputs (49/38) • backspin detection Management functions shall include: • statistical data • pre-trip data (last 40 events) • ability to learn, display and integrate critical parameters to maximize motor protection • a keypad with 40 character display • flash memory The relay shall be capable of displaying important metering functions, including phase voltages, kilowatts, kvars, power factor, frequency and MWhr. In addition, undervoltage and low power factor alarm and trip levels shall be field programmable. The communications interface shall include one front RS232 port and three independent rear RS485 ports with supporting PC software, thus allowing easy setpoint programming, local retrieval of information and flexibility in communication with SCADA and engineering workstations.


Obtain the latest price of TRICONEX MP3101S2 Redundant CARDS