Home > Product > DCS control system > TP854 3BSE025349R1 base

  • TP854 3BSE025349R1 base
  • TP854 3BSE025349R1 base
  • TP854 3BSE025349R1 base
TP854 3BSE025349R1 base TP854 3BSE025349R1 base TP854 3BSE025349R1 base

TP854 3BSE025349R1 base

  • Product ID: TP854 3BSE025349R1
  • Brand: ABB
  • Place of origin: The Swiss
  • Goods status: new/used
  • Delivery date: stock
  • The quality assurance period: 365 days
  • Phone/WhatsApp/WeChat:+86 15270269218
  • Email:xiamen2018@foxmail.com
  • Tags:TP854 3BSE025349R1base
  • Get the latest price:Click to consult

The main products

Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

TP854 3BSE025349R1 base

- ParSet3: (BinaryAddr) Binary input for switching to parameter set 3 Default: Logical “0” (F) - ParSet4: (BinaryAddr) Binary input for switching to parameter set 4 Default: Logical “0” (F) - ParSet1, (SignalAddr) Signals that parameter set 1 is selected. Default: Record as event (ER) - ParSet2: (SignalAddr) Signals that parameter set 2 is selected. Default: Record as event (ER) ParSet3: (SignalAddr) Signals that parameter set 3 is selected. Default: Record as event (ER) - ParSet4: (SignalAddr) Signals that parameter set 4 is selected. Default: Record as event (ER) - MVB_PB_Warn, MVB_PB_Alarm, PB_BA1_Ready…PB_BA4_Ready, PB LA Fault, PB LB Fault These signals only occur when using the MVB process bus (see Operating Instructions for the distributed I/O system RIO 580, 1MRB520192-Uen). Changing the system name The system name is displayed at the upper edge of the MMC.Changing the password This enables an existing password to be replaced by a new one

Analogue outputs

 The analogue output channels on the 216AC61 can be assigned to and scaled for either protection functions or SCS measured variables. The output current (0...20 mA) can be scaled as follows:  SCS measured variables, analogue signals entering via channel 4 of the IBB from the SCS. The range of values is ± 320 and the O/P current scale is ± 200%.

 protection function O/P's and measured variables. The O/P current scale is ± 400%. Channel No. defines to which analogue O/P channels of the 216AC61 unit a measured variable is allocated. Where a system includes several 216AC61 units, the channels are designated according to unit and channel number (e.g. 2001). MinValue scale factor determining the minimum value of the current O/P (0 mA). MaxValue scale factor determining the maximum value of the current O/P (20 mA). Examples of scaling: Display of the measurement by a current function with a rated current In = 1 A.  Scale: Minimum = 0 %, Maximum = 200 %. The O/P of 0...20 mA corresponds to 0...2 A. Display of the measured value of a power function from -50%...+150% Pn.  Scale: Minimum = - 50%, Maximum = 150% 0 mA corresponds to Pn = -50 % 5 mA corresponds to Pn = 0 % 20 mA corresponds to Pn = +150 %.

Obtain the latest price of TP854 3BSE025349R1 base